Access Navigator - Release 1.8 August 2003 9-13
Provision DCS Service
Provision “Groom” DS1 Circuits to Network
5. Set groom DS1 line code to AMI or B8ZS with the following command:
set ds1 <n> linecode <ami|b8zs>
Example: set ds1 10 linecode b8zs
6. Set groom DS1 circuit ID with the following command:
set ds1 <n> id <"id">
Example: set ds1 10 id "Acme Corp DS1#5"
The ID may contain up to 20 characters and must be enclosed in quote marks.
NOTE: DS1 clock must be set to “normal” for normal operation.
7. Set groom DS1 clock source to normal or loop with the following command:
set ds1 <n> clock <normal|loop>
Example: set ds1 10 clock normal
8. Set groom DS1 line buildout (lbo) to required DSX-1 equalization or CSU attenuation with the
following command:
set ds1 <n> lbo <setting>
Example: set ds1 10 lbo 3
The setting is a number from 1 to 9, and is defined as follows:
Setting
Definition
1 Set DSX-1 equalization for 0-133 ft.
2 Set DSX-1 equalization for 133-266 ft.
3 Set DSX-1 equalization for 266-399 ft.
4 Set DSX-1 equalization for 399-533 ft.
5 Set DSX-1 equalization for 533-666 ft.
6 Set CSU attenuation for LBO of 0dB.
7 Set CSU attenuation for LBO of -7.5dB.
8 Set CSU attenuation for LBO of -15dB.
9 Set CSU attenuation for LBO of -22.5dB.
9. Set groom DS1 loop request code detection to on or off with the following command:
set ds1 <n> loopdetect <on|off>
Example: set ds1 10 loopdetect on