Axxius 800 - Release 2.2 5-101
CLI Commands
set
set (ocudp) selftest
Use the set (ocudp) selftest to initiate the OCU-DP card to perform a self test. This request will
display a message to wait 8 seconds before requesting selftest status with the status command.
Syntax: set {ocudp-addr} selftest
Example: set 3:2 selftest
{ocudp-addr}
The {slot:port} address of the OCU-DP card you want to apply the changes to.
set (ocudp) up/down
Use the set (ocudp) up/down to put the OCU-DP line In or Out-of-Service.
Syntax: set {ocudp-addr} {down|up}
Example: set 3:2 up
Set the OCU-DP card in slot 3, port 2 as In-Service.
{ocudp-addr}
The {slot:port} address of the OCU-DP card you want to apply the changes to.
{up|down}
slot Slot number (1-8) where the OCU-DP is located
port Port number or range.
slot Slot number (1-8) where the OCU-DP is located
port Port number or range.
down Set OCU-DP port as Out-of-Service
up Set OCU-DP port as In-Service