Carrier Access Network Device Axxius 800 Manual do Utilizador Página 49

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 568
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 48
Axxius 800 - Release 2.2 1-17
Base Platform
ACO
ACO
The Alarm Cutoff feature permits the operator to temporarily silence the alarm outputs
while testing and repairing the Axxius 800. ACO does not stop alarm messages.
Pressing the ACO pushbutton switch disables the alarm relays and lights the ACO
status LED. This keeps the relay contacts open on the Alarm Output connector. If
another alarm occurs, the alarm relays will be enabled again and the ACO status LED
will go off.
Alarm Cutoff disables the following signals on the Alarm Output connector:
l Critical alarm
l Major alarm
l Minor alarm
The operator also has the option of using the CLI command aco, see aco (Alarm Cut
Off) on page 5-5.