Axxius 800 - Release 2.2 7-5
DS3 Controller Card
Technical Specifications
Service Interfaces Supported
l Dual V.35/.54 Service card (hardened)
l FXO Voice Service card
l ISDN BRI Service card
l OCU-DP Service card
l Quad DS1 ADPCM Service card (hardened)
l Quad T1 Service card (hardened)
l Single Channel POTS Service card (hardened)
l Single Channel POTS with Modem Service card
l Terminal Server Router (TSR) card (hardened)
Network Standards
l ANSI T1-403 and T1.404
Clocking
l Loop-timed from any DS1 within the DS3
l External BITS clock
l Revertive or non-revertive (provisionable) clock switching provides automatic
backup to secondary DS3 should the primary DS3 fail
l Operates as a Stratum 4E device as defined by Telcordia GR-1244-CORE and
AT&T TR 62411
Alarms
l Three visible alarm outputs, critical, major and minor
l Three audible alarm outputs, critical, major and minor
l Alarm Cut-Off for audible alarm outputs
l Ten alarm inputs
l Alarm contacts accessible from external alarm connector
l All alarms are logged in an event log
l Loss of power triggers minor alarm
l Generates SNMP traps for alarming (MIB objects)