Carrier Access Network Device Axxius 800 Manual do Utilizador Página 411

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 568
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 410
Axxius 800 - Release 2.2 10-11
OCU-DP Card
Alarms
Alarms
The OCU-DP cards and supporting Controller Software will support the following
alarms:
Alarm/
Event
Severity Category Description Clear Mechanism
(alarms only)
Card
Detect
Information Equipment OCU-DP card inserted
Card
Removed
Information Equipment OCU-DP card removed
Out of
Service
(OOS)
Major Facility Network sending Out-of-
Service code (OOS) or
card has LOS.
Correct with Network or
replace or deprovision the
card.
Los of
Signal
(LOS)
Major Facility No signal at customer link. Correct with Customer
data path, replace the card,
or reconnect the drop.
Los of
Frame
(LOF)
Major Facility Framing patter not
detected at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Bipolar
Violation
(BPV)
Minor Facility Excessive violations on
customer interface.
Correct with the incoming
signal, or deprovision card.
Vista de página 410
1 2 ... 406 407 408 409 410 411 412 413 414 415 416 ... 567 568

Comentários a estes Manuais

Sem comentários